1. General
Overview - Getting started
3.6.1.
Entering Support Joints from the Structure Menu
3.6.2.
Entering Support Joints interactive
4.3.
Wind Load
4.4.
Snow Load
4.5.
Seismic Loads
4.6.
Load Combinations
4.7.
Calculate or Neglect
the Self Weight
4.8.
Temperature
7.4.
Sway and Natural Frequency
Welcome to
the group of users of Analysis3D.
With Analysis3D
you have purchased one of the most user-friendly analysis tools for steel
constructions you can get.
We hope
this manual will guide you in a clear way through the fascinating world of
Finite Element Analysis and Structural Analysis.
Ever since
1992 Cuylaerts Engineering has been producing structural engineering software
with special focus on a user-friendly interface. Due to this Analysis3D
is being used in over 60 countries worldwide.
To assist
you, there is already a large library of different sections included (Australia
and New Zealand, China GB, Euro, India BIS, Japan JIS, Russia GOST, UK British
Steel, US AISC, and Timber).
The
software performs complex 3D analysis, such as analysis for flexure, torsion,
axial, shear, and deflection. Users can input their desired loads and support
conditions, choose or define any structural sections, produce 3D visualization
and analysis text reports.
Analysis3D also includes Structural Steel
Design that proposes the best section for each member. Each cross-section
is tested for Plastic Tension or Compression, Bending moment (major and minor
axis), Plastic Shear resistance, Reduced plastic shear resistance for the
case of combined Torsion and Shear, Reduced moment resistance for the case of
combined Bending and Shear, Reduced plastic moment resistance for the case of
combined Bending and Axial force or bi-axial bending, Compression buckling,
Lateral Torsional buckling, Combined bending and axial compression
(Chen and Atsuta) and Maximum deflection.
Nonlinear or 2nd order Calculation
takes into account the deformed structure and incrementally calculates the
total effect on the structure.
Analysis3D has become what it is now, thanks
to the comments and remarks of our users. We believe we can always improve Analysis3D,
so we will be grateful to receive your remarks and observations.
Cuylaerts
Engineering cannot be held responsible for possible errors in the software or
the manual, nor for the consequences that arise from the faulty operation or
calculation.
Copyright
1992-2026 by Cuylaerts Engineering. All rights reserved.
Analysis3D calculates two- and three-dimensional Trusses and Frames. These
structures consist of long slender Members that are supposed to behave linear
elastic.
Below you
can find a step-by-step approach to get started:
A: start
from the Structure menu
1)
Select the units and your region to determine which
library of cross sections to use
2)
Select the dimensions and type of structure: 2D or 3D,
Truss (with hinges on the joints) or Frame
3)
Add your joints and their coordinates
4)
Connect the joints with members (beams) and specify
the material and cross section of each beam
5)
Specify all the support joints to give your structure
the required stability
B: using
the Loads menu
1)
Specify the joint loads and/or member loads acting on
the structure
2)
Specify if the own weight of the structure needs to be
calculated or not
3)
Add your wind Loads
C:
Calculate the structure and check the Results
Before entering a construction, be
sure to determine whether the structure is a Frame or a Truss and whether the
structure has 2 or 3 dimensions. You can also select your preferred Units and
Region for the Cross Sections Library.
First enter the Joint coordinates
using the Global Coordinate system.
Members can only be entered when the
Joints are defined.
Joints, Members and all other
structure data can be entered using the Menu Structure or interactively, by
means of the mouse.
Entering the Data interactively has
the following advantage:
1. The result of each minor change
is visualized instantly and can be checked.
2. Selecting a Joint or a Member
with the mouse is much handier than a search through the corresponding lists.
3. Support Joints and Joint Loads
can be entered together with the corresponding Joint.
4. Member Loads can be entered
together with the corresponding Member.
When all Structure data (Joints,
Members, Support Joints, ) are entered, you can define
the loads on the structure (Joint Loads, Member Loads, Wind Load,..)
A number of drawing buttons help you
simplify the drawing control.
When the construction is fully
described, you can Calculate the structure and view the Results.
The Joint Displacements are shown
automatically. Members that fail the requirements for Member Stress or Buckling
are indicated in red. The course of Axial Forces, Shear Forces, Torsion,
Bending Moments and Deflection can be viewed with the Result Menu option Detail
Member Forces.
All compressed members are tested
for Buckling.
By using Member Design, you can
improve and optimize the structure. Analysis3D will check the strength
of each member and propose the minimal Cross Section for the loads applied.
Analysis
for Windows calculates two- and three-dimensional Trusses and Frames. These
structures consist of long slender Members that are supposed to behave linear
elastic.
Before
entering a construction, be sure to determine whether the structure is a Frame or a Truss and whether the structure has 2
or 3 dimensions. You
can enter your data in International or US Units.
First enter
the Joint coordinates.
Members can only be
entered when the Joints are given.
Joints,
Members and all other structure data can be entered with the Menu Structure or interactively, by means
of the mouse.
Entering
the Data interactively has the following advantage:
1. The result of each
minor change is visualized instantly and can be checked.
2. Selecting a Joint or a Member with the mouse is much handier
than a search through the corresponding lists.
3. Support Joints and Joint Loads can be entered together with
the corresponding Joint.
4. Member Loads can be entered together
with the corresponding Member.
A number of drawing shortcuts simplify the Graphics control.
After
defining Joints and Members, you can add Support Joints, Joint Loads and Member
Loads.
When the
construction is fully described, you can calculate the structure and view the Results.
The Joint
Displacements are
shown automatically. Members that fail the requirements for Member Stress or Buckling are indicated in red. The
course of Axial Forces, Shear Forces, Torsion, Bending Moments and Deflection
can be viewed with the Result Menu option Detailed Member Forces.
All
compressed members are tested for Buckling.

The Files
containing the structure data are saved by default with the extension ANA ,
but other extensions are possible.
New erases all structure data in order
to enter a new construction from scratch.
Open loads an existing construction from
disk into memory. The old structure data in memory will be overwritten and
lost.
Save writes the structure data to disk
with the given filename.
Combine loads the structure data from a
given file into memory. The loaded data will be combined with the old structure
in memory.
DXF-Files can be read and saved by this option. Thus, drawings from AutoCad or other drawing tools can be processed and edited.
Reading and writing of DXF-files is restricted to straight lines. The name of
the layer in the drawing will be used as the descriptor for the section used
for each member.
Text File in/out retrieves or saves the structure in a text file with extension 'TXT'.
When the structure has been calculated, the results will be added in the text
file. In this way the results can be used for further processing or importing
in other software like Excel. The layout is identical as the printer
layout.
Library contains
all Cross Section and Material data. The Library also
contains your preferred Language, the color settings for drawing, your
preferred Units used, the Region preference for the Cross Sections and safety
factors for Buckling. At startup Analysis3D loads by default the Library file Analysis.lbr containing all settings that were last saved.
Exit
stops Analysis3D. If some data have been changed since the last saving,
the user will be prompted for a confirmation, after which the data can still be
saved.
3.1. Two or three-dimensional structures
With the
Structure Menu option 2 or 3-Dimensional you can change the dimension of the
construction. By selecting the menu option, the structure toggles between 2 and
3 dimensions.
The small
coordinate system in the bottom left corner also indicates the actual
dimensions selected.
When an
existing 2-dimensional structure is converted into 3 dimensions, the resulting
construction will be unstable due to a lack of restraints in the Z-direction.
An adjustment of the support joints or joint restrictions is required.
With the
Structure Menu option Truss or Frame the type of connections between the
members is established. By clicking this option, the structure toggles between
a Truss and a Frame.
When a
structure only consists of members that are exclusively subjected to axial
Forces, then the structure is called a Truss. When one or more Members are
subjected to shear Forces or bending moments, then the structure should be
considered as a Frame.
In case
that the construction consists of both types of members, start with a Frame and
indicate those members that act as a Truss. Use Hinges on both sides of
the member for that purpose.
A circle in
the origin of the small coordinate system in the bottom left corner indicates
that the structure is a Truss. The circle symbolizes the Hinge.
A Joint is
defined by a Joint Number and the corresponding coordinates given in American
or International Units. The units are specified by the Structure Menu option
Units. In International Units, Joint coordinates can be entered in meter or mm
as indicated by the check box. The Global coordinate system for any structure
is indicated by the small coordinate system in the bottom left corner of the
screen.
The Joints
can be entered either with the menu or interactively with the mouse.
To add,
change or remove Joints in the Joint list simply select the Joint option from
the Structure menu.
Adding
new Joints: Enter
the Joint Number and his coordinates to the left of the ADD button. When
entering Joints in a 2-dimensional construction, Z-coordinates will not be
accepted.
To add the
Joint data to the list simply press ENTER in the last edit box, or press the
ADD button. After each new added Joint, the Joint Number will automatically
increase by one.
Removing
Joints: Select the
Joint(s) you want to remove and press the REMOVE button. The program requires
that all Joint Number follow without a gap. The gap that is caused by the
removal of the Joints will automatically be filled when the window is closed.
All Joints after the gap will be moved forward.
Changing Joints: This can be done in 3 ways:
1) Type
the Joint Number and press ENTER.
2) Double
Click on the Joint Number with the mouse.
3) Select
the Joint Number and click the Edit button.
In both
cases the Joint will be removed from the list to the edit boxes, where you can
edit the joint data. Don t forget to add the Joint to the list after editing.
Editing the Joints directly in the list is not allowed.
The COPY
button enables you to copy or move
the selected Joints over a given distance in all directions.
The selected
Joints can be moved or copied over a given distance in the X, Y or Z
direction with the COPY button from the Joint window.
All the
intermediate Members will be copied also. This simplifies entering a large
construction with identical substructures.
If the
selected Joints only have to be moved instead of copied, select the MOVE button
in the Copy Joints window.
To change
an existing Joint, double click with the left mouse button on the Joint you
want to change. A new window will appear to allow editing of the selected joint
and the selected Joint number will turn red.
To deselect
a Joint, press the right mouse button.
From this window you can change the
Joint coordinates directly. Use the arrow buttons to change the joint number
you want to change. The +button enables you to add a new Joint.
Using - will delete the current Joint.
The tabs
SUPPORT and LOAD allow you change the Support Joints and Joint Loads of the selected Joint.
This method
allows you to view each change on the screen as soon as it is entered.
It is not necessary to apply this
rule, since Analysis3D will automatically check begin and end Joint and
makes these changes for you.
The names
of the Cross Sections
need to correspond to the ones defined in the library of Cross Sections.
The
Material name must correspond to the Material name in the Material Data list.
The Members
of a Frame can have Hinges and can be rotated over a
certain Angle around its
local x-axis.
Members can
be entered either with the menu or interactively with the mouse.
To add,
change or remove Members in the Member list simply select the Members option
from the Structure
menu.
Adding
new Members: Enter
the Member Number begin and end Joint, the name of the Cross Section and in
case of a Frame: the Hinges and the rotation Angle.
To add the
Member data to the list simply press ENTER in the last edit box, or press the
ADD button. After each new added Member, the Member Number will automatically
increase by one.
Removing
Members: Select
the Member(s) and press the REMOVE button. The program requires that all Member
Number follow without a gap. The gap that is caused by the removal of Members
will automatically be filled when the window is closed. The Member numbers
after the gap will be moved forward.
Changing
Members: This can
be done in two ways:
1) Type the Member Number and press ENTER.
2) Select the Member with the mouse and press the right mouse button.
In both
cases the Member will be moved from the list to the edit boxes, where you can
edit the Member data. Don t forget to add the Member to the list after editing.
Editing the Members directly in the list is not allowed.
The Cross Section
button lets you change the Cross Section of all Members with a given
Section. For instance, you can change all Members with Cross Section IPE200
into IPE240.
The Material
button lets you change the material name of all Members of a given
material. For instance, you can change all Members with Material FE360 to
FE450.
With the Hinge
button you can change the Hinges of the selected Members.
To enter a new
Member select begin and end Joint Number with the left mouse button. A
selected Joint Number turns Red. Use the right mouse button to deselect a
Joint.
The new
Member window will enable you to add the other properties of the Member. Analysis3D
assumes that the new Member has the same properties as the last entered Member,
but this can be overwritten.
The names of
defined Cross Sections and Material Data can be
selected from the drop-down list.
To change an existing Member
select begin and end Joint Number with the left mouse button. A window in the
top right of the screen will enable you to change the properties of the Member.
At the same time the Local Coordinate System of the selected Member is displayed.
Once a Member
has been selected, it can be removed, together with the Member Loads, by
pressing the - button. To add a member, press the + button.
To enter
the Member Loads of
the selected Member press the LOAD tab.
This method lets you view each
change or new Member on the screen instantly.
A Frame can contain one or more Members that have a Hinge on one or
both sides. A Hinge indicates that the member is exclusively subjected to axial
Forces on the side of the Hinge.
The
following symbols are used to indicate the Hinges:
0 : The Member has no Hinges.
B : The Member has one Hinge at the Begin
Joint.
E : The Member has one Hinge at the End
Joint.
2 : The Member has two Hinges at the begin and end
Joint.
A Truss by
definition consists of members with Hinges on both sides. Hence Hinges cannot
be defined in case of a Truss.
The resulting Rotation Angle can be
represented graphically by selecting the Member with the mouse. The Local
Coordinate System of
the selected Member will be displayed. These coordinates will help you to
determine the positive local x-axis. The local y-axis always coincides with the
major Cross Section Moment of Inertia Ix.
Since
Members in a Truss are
exclusively subjected to tension and compression, it has no influence whether
the Members are rotated or not.
All Joints, Support Joints, Joint Loads, Joint Displacements and Reactions are referenced to the Global
Coordinate System.
The Global
Coordinate System consists of a set of right-hand orthogonal axes X, Y and Z
which are oriented as shown in the left bottom corner of the screen.
The
representation of the Global Coordinate System will follow the point of view.
It will also indicate whether the Structure is a TrussFrame or a Frame, and whether the structure has two
or three dimensions.

IN
THEORY

The
local x-axis runs parallel with the Member through the middle of the Cross Section.
The Joint with the smallest global X
coordinate is the begin Joint. This means that the local x-axis always points
from the begin Joint to the end Joint of a Member.
In case
that the global X coordinates are equal, the Joint with the smallest Y
coordinate is the begin Joint. When both X and Y coordinates are equal, the
smallest Z coordinate indicates the begin Joint.
The
local z-axis will always be oriented parallel to the global XZ plane.
The
local y-axis will be oriented so that its positive direction projects onto
the positive global Y-axis.
In the
special case that the local x axis is parallel to the global Y axis (e.g., a
vertical Member), the local z-axis will have the additional restriction that it
will be parallel to the global Z axis and extend in the positive Z direction.
IN
PRACTICE
Put into
practice, Analysis3D will take care that the Member Data coincides with
the local coordinate system.
For your
information the local coordinate system of the Member is shown additionally on
the screen when a Member is selected with the mouse (by selecting both joint numbers of that member).

A Support
Joint is defined by the Joint
Number and the restrictions per axis.
To indicate
the Restraints, we use the following agreement:
When there is no Restraint in the given
direction, the corresponding direction will be left blank using a space.
R : any movement is Restrained in the given
direction. Displacements will stay zero.
D : the support experiences a forced Displacement
in the given direction. The magnitude of the displacement it given by Dx,
Dy or Dz.
S : a Spring supports the joint in the
given direction. Dx, Dy or Dz indicate the Spring
constant.
Rx, Ry and Rz indicate a
translation Restraint in the Global
X-, Y- and Z-direction. When for instance Rx = R, translation is restricted in
the Global X-direction. As a result, a Reaction Force in the X-direction will
act upon the structure from the Support Joint.
Mx, My and Mz
indicate a rotation Restraint round the Global X-, Y- and Z-direction. When for
instance Mx = R, rotation is restricted round the Global X-axis. As a result, a
Reaction Moment round the X-axis will act upon the structure from the Support
Joint.
Since the
Members in a Truss are
connected with Hinges, Trusses cannot have rotation Restraints.
The Joints
in a two-dimensional Frame can only have translation Restraints in the Global
X- and Y-direction and a rotation Restraint round the Z-axis.
Dx, Dy and Dz indicate
the magnitude of the forced displacements or spring constants. The meaning of
the value depends on the contents of the corresponding translation
Restraint.
Forced displacements can
be entered in mm or inches depending on the Units option from the Structure
Menu. Accordingly, Spring constants can be given in kN/cm
or Kips/inch.
Examples:
Pinned support:
Rx =
R
Ry = R
Mz =
Horizontal roller:
Rx =
Ry =
R
Mz =
Fixed support:
Rx =
R
Ry =
R
Mz = R
Since the
drawing of the support can only show the Restrictions in two dimensions, the
drawing will change according to the point of view in a three-dimensional
structure.
Support
Joints can be entered both with the Menu and with the mouse.
To add,
change or remove Support Joints in the Restraints list simply select the
Support Joint option from the Structure
menu.
Adding
new Support Joints: Enter
the Joint Number and the restrictions for each axis. Frames can also have rotation
Restraints besides the translation Restraints.
To add the
Support Joints to the list simply press ENTER in the last edit box, or press
the ADD button. After each new added Support, the Support Joints Number will
automatically increase by one.
Removing
Restraints: Select
the Support(s) and press the DELETE button.
Changing Restraints: This can be done in 3 ways:
1) Type
the Support Number and press ENTER.
2) Double
click the Joint number with the left mouse button.
3) Select
the Joint number and press the Edit button.
In both
cases the Support Joint will be removed from the list to the edit boxes, where
you can edit the Restraint data. Don t forget to add the Support Joints to the
list after editing. Editing the Supports directly in the list is not allowed.
To add,
change or remove Support Joints first select the JointJoint by double clicking the left mouse button. In
the lower right corner of the screen appears a window to enter the Joint
coordinates. The Support Joints can be edited by selecting the SUPPORT tab.
To clear a Support Joint clear all
restraints. Pressing the - button will also delete
the Joint displayed.
This method
allows you to view each change on the screen as soon as it is entered.
Analysis3D has an extensive library of
standard Member Cross
Sections. The list can be easily updated.
The Units and Region option from the
Structure Menu allows you to select a different Library of Cross Sections.
Also, the units are specified by the same Structure Menu selection.
You can also download or save a
different file with Cross Sections using the File menu from the top left of the
Cross Section window. Analysis3D offers a wide selection of Libraries
from different regions to choose from. E.g., Euro, US AISC, UK British Steel,
Russia GOST, China GB, India BIS, Japan JIS, Australia and New Zealand and
Timber.
Each Cross
Section has a unique Section Name:
Shape: Identifies the section out of the following choices: I-section,
U-section or channel, L-section, T-section or half I-section, Rectangular box, Circular tube, Full section.
Fabric: How was the section made: Rolled or Welded
Ax : the
Cross Sectional Area in [cm2] or [inch2]
h : total
height of the section in [mm] or [inch]
d : total
width of the section in [mm] or [inch]
tw : web thickness in [mm] or [inch]
tf : flange thickness in [mm] or [inch]
r : radius
between flange and web in [mm] or [inch]
Ix : the
Cross Section Moment of Inertia about the x axis in [cm4] or [inch4]
( as a result of a Load along the local y-axis )
Iy : the Cross Section Moment of Inertia about the y axis
[cm4] or [inch4]
( as a result of a Load along the local z-axis )
It : the Cross Section Torsional Constant [cm4] or [inch4]
(as a result of a Moment round the local x-axis)
For a round
section the Torsional Constant is equal to the polar Moment of Inertia.

|
|
|
|
|
|
|
|
|
|
Wx, Wy : Elastic Section Modulus in [cm3] or [inch3]
Zx, Zy : Plastic Section Modulus
in [cm3] or [inch3]
ex : the
distance from the neutral line of the Member to the outside of the Member along
the main axis of that Member. In the case of asymmetrical Cross Sections this
will usually be the longest distance.
ey : the distance from the neutral line of the Member to
the outside of the Member along the secondary axis of that Member.
For both ex and ey it is important to use the longest distance
to the outside of the member as shown in the figure below.

et :
for closed sections
et is the greater of ex or ey. In the case of open
sections et is the thickness of the thickest part of the section. This usually
is the maximum flange thickness of the beam cross section.
et
for full rectangular beams: b (see Torsional Constant above)

et
for full open sections: maximum thickness (of flange or body)
M :
the Mass of
the Member per meter [kg/m] or [kg/ft]
Each
Material is defined by:
Material: a unique name for the
Material
E : the Modulus of Elasticity in [kN/cm ] or
[Kips/inch ]
G : the Shear
Modulus in [kN/cm ] or [Kips/inch ]
G = E / 2(1+v) with: v = Poisson constant;
for metals v = 1/3
Re :
the Limit Stress of
the material in [N/mm ] or [Kips/inch ] = 0.7 Yield Point or Tensile Strength.
The Linear
Coefficient of Expansion in 10-6 1/K.
The units
are specified by the Structure Menu option Units.
All data can be expressed in
International SI units, in US Units or Continental Units. You can select your
preferred Units from the drop-down list.
It is possible to enter the Joint
coordinates in International SI Units, the Forces in American Units and view
the results in both International and American Units. Toggling between Units
can introduce a minor deviation due to rounding off.
Below are the most commonly used
Units with the corresponding conversion factors.
|
|
SI Units |
US Units |
Continental Units |
|
Joint Coordinates: |
meter [m] |
foot [ft] |
meter [m] |
|
Forces: |
kNewton [kN] |
thousands of pounds [Kips] |
kilogram [kg] |
|
Moments: |
[kNm] |
[Kip-ft] |
[kgm] |
|
Distributed Load: |
[kN/m] |
[Kip/ft] |
[kg/m] |
|
Joint Displacements: |
[mm] |
Inch [in] |
[mm] |
|
Stresses: |
[N/mm ] |
[Kips/in ] |
[kgf/mm ] |
1 foot = 0.3048 meter
1 inch = 25.4 mm
1 pound [lbf] = 4.44822 Newton
1 kgf = 9.80665 Newton
1 N/mm = 1MPa
Region
You can select
from the drop-down list the Region for which the Cross-Sectional
Data will be selected.
The following Regions are available
with Lists of Cross Sections:
Australia New Zealand
China GB
Euro
India BIS
Japan JIS
Russia GOST
UK British Steel
US AISC (available both in metric and in imperial units)
Other Sections
Timber
On request, this
list can be easily expanded or amended to fit your needs.
This selection allows you to choose
which International or Local Standard will be used for optimizing the structure
with the Member Design or Detailed Design options from the Result Menu.
Analysis3D offers the following
Standards to choose from:
AISC ASD
AISC LRFD
BS 5950
CISC 94
Eurocode 3
Your selection of Units and Region
needs to be stored in the Library file for this to
remain active when you restart Analysis3D as your default selection.
A Joint
Load is defined by the Joint Number and the Forces and Moments acting on that
Joint.
You can use
up to 9 different Load Cases. Each Load Case is defined by the Load Case
number from 1 to 9. The importance of each Load Case is determined with the
Load Combinations
option from the structure menu.
The Forces
in kN or Kips are parallel with the Global coordinate
System as drawn in
the left bottom of the screen. Thus, a positive Force Fy
points up. By default, Forces are represented in red.
Moments in kNm or Kips-ft are positive according the right-hand rule
round the respective global coordinate axis. In two-dimensional Structures the
Moments are drawn as an arc, in the case of three dimensions the moments are
drawn as an arrow, by default painted purple.
The units
are specified by the Structure Menu option Units and Region.
Since the
Members in a Truss are
connected with Hinges, Trusses cannot have Moments as Joint Loads.
The Joints
in a two-dimensional Frame can only have Forces in the Global X- and
Y-direction and a Moment round the Z-axis.
Joint Loads
can be entered from the Structure Menu or interactively.
To enter
Joint Loads interactively, first select the desired Joint and press the LOAD tab.
A Member
Load is defined by the Member Number
and the Forces in kN or Kips and Moments in kNm or Kip-ft acting on that Member.
You can use
up to 9 different Load Cases. Each Load Case is defined by the Load Case
number from 1 to 9. The importance of each Load Case is determined with the Load
Combinations
option from the structure menu.
There are five different basic Load
Types for Member Loads. For simplicity these five Load Types get an
arbitrary Load Type Number as indicated below. But you can also simply click at
the bottom of the screen on the Load Type you want to use and Analysis3D will
select the corresponding Load Type number for you:
1 : A Point Load F in [kN] or [Kips] along the x-, y- or z-axis, at a distance a
in [m] or [ft] from the begin Joint.

2 : A Moment M in [kNm] or [Kip-ft] round the x-, y- or z-axis, at a distance
a in [m] or [ft] from the start Joint.

3 : A Distributed Load q
in [kN/m] or [Kips/ft] along the x-, y- or
z-axis.

4 : A Symmetrical Trapezoidal
Distributed Load q in [kN/m] or [Kips/ft] along
the x-, y- or z-axis with transition a in [m] or [ft].

5 : a Non Symmetrical
Trapezoidal Distributed Load along the x-, y- or z-axis that starts with a
Load Q1 in [kN/m] or [Kips/ft] at a distance a in [m]
or [ft] from the begin Joint and that is b [m] or [ft] long. Thus, the end Load
Q2 in [kN/m] or [Kips/ft] is on a distance a+b from the begin Joint.

L/G: Forces and Moments can be entered
according the Global
or the Local coordinate System.
Entering L or G in the L/G field makes this choice. Forces that are parallel or
perpendicular to a Member with a slope can easily be
entered with the Local Coordinate System.
Member
Loads can be entered from the Structure Menu or interactive with the mouse.
To enter Member Loads interactively,
first select the Member with the mouse, and press the LOAD tab. Select the Load
case and Load type by using the arrow buttons. To delete a load, all forces
have to be cleared.
Wind
Load is calculated according to Eurocode 1991-1-4 or according to ASCE 7-16.
Analysis3D also provides a General option not restricted by a national code.
Wind Load according to Eurocode 1991-1-4 (EN
1991-1-4:2005+A1 April 2010)
For Wind Load calculations there are
basically 2 options:
-
for an open structure only the wind load on the beams
is calculated
-
for a closed structure the calculation assumes the
walls are closed and the wind acts on the surface of the entire closed area.
Wind Load calculation according to
Eurocode 1991-1-4 starts from the fundamental value of the basic wind velocity
Vb0. This is the characteristic 10 minutes mean wind velocity, irrespective of
wind direction and time of year, at 10 m above ground level, in open country
terrain. It corresponds to a mean return period of 50 years.
The Basic wind velocity Vb = Cdir . Cseason . Cprob . Calt . Vb0.
Cprob is calculated with the input given using the formula: ![]()
The mean wind velocity Vm(z) at height z above the terrain is calculated as: Vm(z) = Cr(z).Co(z).Vb
The roughness factor Cr(z) is
calculated based in the Terrain Category specified and the formula
Cr(z)= kr. ln(z/z0)
Peak velocity pressure is given by qp(z) = [1+7Iv(z)] .ρ. Vm2(z)
Where Iv(z) is the turbulence
intensity which allows to take into account the contribution from short term
fluctuations Iv(z) = k1 / [Co(z). ln(z/z0)].
The wind pressure acting on the
external surface: We = qp(z).Cp
Where Cp is the pressure coefficient
as indicated in the overview per zone.
For walls:

For duopitch roofs:

Please note
that Eurocode requires to investigate the option with positive and with
negative pressure coefficients. For duopitch roofs, 4
combinations are required for investigation, consisting on positive and
negative pressure coefficients on each side of the roof.
Finally the forces on the structure
are calculated using Fwe = CsCd.∑ We.Aref.
The button Calculate determines the
pressure coefficients as per Eurocode. However, the user has the freedom to
overwrite any number before applying the Wind Loads to the structure. When
pressing the button Apply Wind Load, Analysis3D will use the numbers
displayed for the final calculation.
To apply these forces, the user can
select the Load Case the Wind Loads should be attributed to and they will be
added to the list of Member Loads.
With the option Load Combination
from the main menu, the user can choose the relative weight of the Wind Load
for the combined calculation.
Wind Load according to ASCE 7-16
For Wind Load calculations there are
basically 2 options:
-
for an open structure only the wind load on the beams
is calculated
-
for enclosed or partially enclosed buildings, the
calculation assumes the walls are closed and the wind acts on the surface of
the entire area.
Wind Load calculation according to
ASCE 7-16 starts from the basic wind speed Vb. This is the nominal design
3-second gust wind speed at 10m (33ft) above ground for Exposure C category.
These correspond to approximately a 3% probability of exceedance in 50 years.
The velocity pressure q is
calculated as q = 0.613 . Kz.
Kzt. Kd. Vb
Where the Topographic Factor Kzt is determined by Kzt = (1 + K1 . K2 . K3) and derived from figure 26.8-1 below.


The velocity pressure exposure
coefficient Kz = 2.01 . (z/zg)2/alpha. For z < 15 ft (4.6m) : Kz = 2.01 . (15/zg)2/alpha
The terrain exposure coefficients
are derived from Table 26.11-1 below

Kd is the Wind Directionality factor and can be derived from table 26.6-1
below.

Design wind pressures for the MWFRS (Main Wind Force Resisting System in Directional Procedure) of buildings of all heights is determined by the
following equation: p = q . G .
Cp qi . GCpi (N/m2 )
External pressure coefficients are
calculated by Analysis3D based on Figure 27.3-1 below


And the
wind loads are applied according to :

All calculated values are shown in
grey cells the values that require input are left white. However; most of the
non-calculated cells are completed with default values.
The button Calculate determines the
pressure coefficients as per Eurocode. However, the user has the freedom to
overwrite any number before applying the Wind Loads to the structure. When
pressing the button Apply Wind Load, Analysis3D will use the numbers
displayed for the final calculation.
To apply these forces, the user can
select the Load Case the Wind Loads should be attributed to and they will be
added to the list of Member Loads.
With the option Load Combination
from the main menu, the user can choose the relative weight of the Wind Load
for the combined calculation.
Wind Loads for General application
Since it is
almost impossible to include each and every standard for each and every
country, the General option minimizes the predetermined calculations and just
allow the user to let Analysis3D apply the Wind Loads as specified by the user
(according to the national standard applicable).
Based on
the velocity pressure and the pressure coefficients specified by the user,
Analysis3D will calculate the Wind Load for each wall and roof. For the
coefficients, the following rule applies: positive pressure coefficients are
pointing towards the building, negative coefficients are pointing away from the
building.
For Open structures, Analysis3D will
only calculate the wind on the surface of the steel structure, assuming no
walls exist.
Analysis3D
offers 3 options to calculate Snow Loads. Snow Loads can be defined according
to ASCE/SEI 7-16, according to Eurocode 1 - Actions on structures - Part 1-3 or
using a General method not restricted by any specific
standards.
Snow Load according to ASCE/SEI 7-16
Before we
can apply any snow loads to our structure, we need to know the ground snow load
(pg) at our location, which can be found
using Figure 7.2-1 from ASCE 7-16.
Also, you
can directly find the ground snow load for your location through online Hazards by
Location tool,
provided by ATC.
In some
special cases, site-specific case studies are needed to determine ground snow
loads and therefore cannot directly be found on the map provided.
The snow
load that is applied to our structure is not the ground snow load, but in most
cases, the flat roof snow load (roof slope ≤ 5 ).
The flat
roof snow load is calculated using formula below:
pf = 0.7 Ce Ct Is
pg
Where:
pg = Ground Snow Load
Ce = Exposure Factor from table
7.3-1 below

Where the
Surface Roughness Categories as defined as below:
Surface Roughness B: Urban and suburban areas,
wooded areas, or other terrain with numerous, closely spaced obstructions that
have the size of single-family dwellings or larger.
Surface
Roughness C: Open terrain with scattered obstructions that have heights
generally less than 30 ft (9.1 m). This category includes flat, open country
and grasslands.
Surface
Roughness D: Flat, unobstructed areas and water surfaces. This category
includes smooth mud flats, salt flats, and unbroken ice
Ct = Thermal Factor from the Table 7.3-2
below

Is = Importance Factor: The value for Is
shall be determined from Table 1.5-2 based on the Risk Category from Table
1.5-1 below.


Sloped Roof
Snow Loads: ps
The Snow
loads acting on a sloping surface shall be assumed to act on the horizontal
projection of that surface. The sloped roof snow load, ps,
shall be obtained by multiplying the flat roof snow load, pf
, by the roof slope factor, Cs:
ps = Cs pf
The values
of Cs for warm roofs and cold roofs are determined from Figure 7.4-1
below.
For roofs
with an unobstructed slippery surface that allows snow to slide off the eaves,
the roof slope factor Cs shall be determined using the dashed line in Fig.
7.4-1.
For all
other roofs, the solid line in Fig. 7.4-1 shall be used to determine the roof
slope factor Cs.

After
Calculating the Snow Load, we can use the Apply Snow Load button to distribute
the Snow Load accordingly over the roof.
Snow Load according to Eurocode 1 (EN 1991-1-3:2003)
In order to
calculate the Characteristic Snow Load on the ground Sk,
we first, need to select the climatic region from the drop-down box.
In each
climatic region a given load-altitude correlation formula applies and this is
given in Table C.1 below. Different zones are defined for each climatic region.
Each zone is given a Zone number Z, which is used in the load altitude
correction formula.
The
National Annex specifies the characteristic values to be used. To cover unusual
local conditions the National Annex may additionally allow the client and the
relevant authority to agree upon a different characteristic value from that
specified for an individual project.
Annex C of
EN 1991-1-3:2003 gives the European ground snow load map. The National Annex
may make reference to this map in order to eliminate, or to reduce,
inconsistencies occurring at borderlines between countries.

Where:
Sk is the characteristic snow load on
the ground [kN/m2]
A is the site altitude above Sea Level [m]
Z is the zone number given on the map.
The Snow
Load on the Roof (s) is calculated usin the formula
below:
s = Ct Ce μi sk
Where the
thermal coefficient Ct should be used to account for the reduction
of snow loads on roofs with high thermal transmittance (> 1 W/m2 K), in
particular for some glass covered roofs, because of melting caused by heat
loss. For all other cases: Ct = 1,0
Ce = Exposure coefficient determined
from the table below.

The snow
load shape coefficient 1 that should be used for sloped roofs is given in
Table 5.2 below. The values given in Table 5.2 apply when the snow is not
prevented from sliding off the roof. Where snow fences or other obstructions
exist or where the lower edge of the roof is terminated with a parapet, then
the snow load shape coefficient should not be reduced below 0,8.
The values
of 1 apply for undrafted load arrangements, 2 applies for drifted load
arrangements,

The following 3 cases need to be
investigated for a pitched roof/

After
Calculating the Snow Load, we can use the Apply Snow Load button to distribute
the Snow Load accordingly over the roof.
Snow Load for general application
Since it is
almost impossible to include each and every standard of each and every country,
the General option minimizes the predetermined calculations and just allow
the user to let Analysis3D apply the Snow Load on the Roof as given by the user
(according to the national standard applicable).
Analysis3D
offers 3 options to calculate Seismic Loads. Seismic Loads can be defined
according to Eurocode 8 (EN 1998: 2004) or according to ASCE/SEI 7-16 or using
a General method not restricted by any specific
standards.
Seismic Load
according to ASCE/SEI 7-16
First, we identify the map data properties for our building. We can
obtain the seismic map data from free tools such as the ASCE 7 Hazard Tool at https://asce7hazardtool.online.
Here we can
find the values for:
SS: the Long-period transition period, the
spectral response acceleration parameter at short periods:
S1: the spectral response acceleration
parameter at a period of 1s:
R is the
response modification factor from ASCE/SEI 7-16 Table 12.2-1
All fields
that require input are white Edit boxes. The fields that are the result of a
calculation are shaded. When all input values are entered, we can determine the
results by pressing the Calculate button.
Site Class
is a classification assigned to a site based on the types of soils present and
their engineering properties, as defined in the table 20.3-1 below. The
calculations in Analysis3D are limited to the Site classifications A to D.

The Risk
Category is found in the table 1.5-1 below.

The
structure type is determined from the table 12.8-2 below.

The Design
earthquake spectral response acceleration parameters at short periods, SDS,
and at 1-s periods, SD1, are determined from the equations:
SDS = 2/3 SMS
SD1 = 2/3 SM1
Where the
MCER spectral response acceleration parameters for short periods (SMS)
and at 1 s (SM1), adjusted for site class effects, are determined by
equations
SMS = Fa SS
SM1 = Fv
S1
With Fa and
Fv from the tables 11.4-1 and 11.4-2 below


The Risk
Category is calculated from the tables 11.6-1 and 11.6-2 below. But for Risk
Category I, II, or III structures located where the mapped spectral response
acceleration parameter at 1-s period, S1, is greater than or equal to 0.75
shall be assigned to Seismic Design Category E. Risk Category IV structures
located where the mapped spectral response acceleration parameter at 1-s
period, S1, is greater than or equal to 0.75 shall be assigned to Seismic
Design Category F

The
approximate fundamental period (T), in seconds, shall be determined from the
following equation:
T =Ct hnx
where hn is the structural height
and the
coefficients Ct and x are determined from Table 12.8-2 below.

The
effective seismic weight, W, of a structure shall include the dead load, above
the base and other loads above the base as listed below:
1. In areas
used for storage, a minimum of 25% of the floor live load shall be included.
EXCEPTIONS:
a. Where
the inclusion of storage loads adds no more than 5% to the effective seismic
weight at that level, it need not be included in the effective seismic weight.
b. Floor
live load in public garages and open parking structures need not be included.
2. Where
provision for partitions is required by Section 4.3.2 in the floor load design,
the actual partition weight or a minimum weight of 10 psf
(0.48 kN∕m2) of floor area, whichever is greater.
3. Total
operating weight of permanent equipment.
4. Where
the flat roof snow load, Pf , exceeds 30 psf (1.44 kN∕m2),
20% of the uniform design snow load, regardless of actual roof slope.
5. Weight
of landscaping and other materials at roof gardens and similar areas
For
Analysis3D to be able to calculate the effective weight, the input is required
for each Load Case. We have the possibility to apply a combination coefficient
to each Load Case (which is fully independent from existing Load case factors).
As an example, we would apply a combination coefficient of 1.0 to Dead Loads
and a combination coefficient of 0.25 to Live Loads.
The seismic
base shear, V, in a given direction shall be determined in accordance with the
following equation:
V = CsW
where
Cs = the seismic response
coefficient
W = the effective seismic weight.
The seismic
response coefficient, Cs, is determined in accordance with equation
Cs = SDS / (R/Ie)
where
Ie = the Importance Factor determined
in accordance with Table 1.5-2 below.
R is the response modification factor from
ASCE/SEI 7-16 Table 12.2-1

The value
of Cs shall not exceed the following:

When the
value of the seismic base shear is calculated. We can distribute the base shear
over the different floors.
The lateral
seismic force induced at any level is determined from the following equations:

Where
Cvx = vertical distribution factor;
V = total design lateral force or shear at the
base of the structure
wi and wx = portion of
the total effective seismic weight of the structure (W) located or assigned to
level i or x; hi and
hx = height from the base to level i or x
k = an exponent related to the structure period
as follows:
for structures that have a period
of 0.5 s or less, k = 1;
for structures that have a period
of 2.5 s or more, k = 2; and
for structures that have a period
between 0.5 and 2.5 s, k shall be 2 or shall be determined by linear
interpolation between 1 and 2
We can use
the Apply Seismic Load button to distribute the Seismic base shear accordingly
over the different levels of the structure. The factors Ex and Ez are the multipliers used for the Seismic Loads for each
direction.
Seismic Load according to Eurocode EN 1998:2004
Analysis3D
applies the Lateral force method of analysis. This type of analysis may be
applied to buildings whose response is not significantly affected by
contributions from modes of vibration higher than the fundamental mode in each
principal direction. This requirement is deemed to be satisfied in buildings
which fulfil both of the two following conditions:
a) they
have fundamental periods of vibration T1 in the two main directions which are
smaller than the following values
b) they
meet the criteria for regularity in elevation given by EC8 section 4.2.3.3.
All fields
that require input are white Edit boxes. The fields that are the result of a
calculation are shaded. When all input values are entered, we can determine the
results by pressing the Calculate button.
The ground
type is determined from table 3.1 below.

The Shape
of the elastic response spectrum: If deep geology is not accounted for, the
recommended choice is the use of two of spectra: Type 1 and Type 2. If the
earthquakes that contribute most to the seismic hazard defined for the site for
the purpose of probabilistic hazard assessment have a surface-wave magnitude, Ms, not greater than 5,5, it is recommended that the Type 2
spectrum is adopted.
T1
is the fundamental period of vibration of the building for lateral motion in
the direction considered. For buildings with heights of up to 40 m the value of
T1 (in s) may be approximated by the
following expression: ![]()
where Ct
is 0,085 for moment resistant space steel frames, 0,075 for moment resistant
space concrete frames and for eccentrically braced steel frames and 0,050 for
all other structures; H is the height of the building, in m, from the
foundation or from the top of a rigid basement.
q is the behaviour factor and is specified by the National Annex.
The ranges are given by table 6.1 below.
Design
ground acceleration on type A ground (ag = ϒ1 . agR); can be found from the National Annex.
agR is
the reference peak ground acceleration on type A ground
ϒ1 is
the importance factor. The value of ϒ1 for importance class II shall be,
by definition, equal to 1.0. NOTE The values to be ascribed to ϒ1 for use
in a country may be found in its National Annex. The values of ϒ1 may be
different for the various seismic zones of the country, depending on the
seismic hazard conditions and on public safety considerations. The recommended
values of ϒ1 for importance classes I, III and IV are equal to 0,8, 1,2
and 1,4, respectively.
β is the lower bound factor for the
horizontal design spectrum. NOTE The value to be ascribed to β for use in a country can be found in its
National Annex. The recommended value for β is 0,2.
Mass of
building: the masses to be used in a seismic analysis should be those
associated with the load combination: ![]()
Where G
equals the Dead load and Q the Imposed load.
is the combination coefficient
for a variable action i, to be used when determining the effects of the design
seismic action. This can be set to 0.3 by default. Since Analysis3D cannot
determine which Loads are Dead Loads and which are Imposed Loads to be taken as
part of the Seismic Load, we need to clearly identify which Loads to account
for.
Dead Loads
need to be given a combination coefficient of 1 by the user and loads that
don t need to be taken into account as Seismic action, need to be given a
combination coefficient of 0.
![]()

For the
horizontal components of the seismic action the design spectrum, Sd(T), is
defined by the following expressions:


Where the
values of S, TB(S), TC(S) and TD(S) are found
in the tables 3.2 and 3.3 below.


Base
shear force: The
seismic base shear force for each horizontal direction in which the building is
analyzed, shall be determined using the following expression:

Distribution
of the horizontal seismic forces:
The
fundamental mode shapes in the horizontal directions of analysis of the
building may be approximated by horizontal displacements increasing linearly
along the height of the building.
The seismic
action effects shall be determined by applying, to the two planar models,
horizontal forces Fi to all storeys.
![]()
Where:
Fi is the horizontal force acting on storey i;
Fb is the seismic base shear;
zj, zj are the heights
of masses mi mj above the level of application of the
Seismic action (foundation or top of a rigid basement).
Mi,mj are the storey
masses.
We can use
the Apply Seismic Load button to distribute the Seismic base shear accordingly
over the different levels of the structure. The factors Ex and Ez are the multipliers used for the Seismic Loads for each
direction.
Seismic Load for general application
Since it is
almost impossible to include each and every standard of each and every country,
the General option minimizes the predetermined calculations and just allow
the user to let Analysis3D calculate the Mass of the building depending on the
input given by the user (according to the national standard applicable). The
Mass of the building is calculated using the combination coefficients given for
each Load Case.
Only 1
Correction factor is applied (as a combination of all factors from the national
standard) to calculate the Seismic base shear.
The Apply
Seismic Load button will distribute the Seismic base shear over the different
levels of the building.
The seismic
action effects shall be determined by applying, to the two planar models,
horizontal forces Fi to all storeys.
![]()
Where:
Fi is the
horizontal force acting on storey i;
Fb is the
seismic base shear;
zj, zj are the heights of masses mi mj
above the level of application of the Seismic action (foundation or top of a
rigid basement).
Mi,mj are the storey
masses.
We can use
the Apply Seismic Load button to distribute the Seismic base shear accordingly
over the different levels of the structure. The factors Ex and Ez are the multipliers used for the Seismic Loads for each
direction.
All Joint
Loads and Member Loads have a Load Case number from 1 to 9. This number
corresponds to a given Load Case Name and Load Factor. The only purpose of the
name is to act as a reminder for the type of Load Case that is used.
Load Case number 0 is
reserved for the self-weight of the structure.
The Load factor is used to calculate
the actual importance of a given Load Case. A Load Factor of 2 will double all
Loads on the construction with this Load Case number. The total Load that is
applied to the structure can be a combination of 9 different load cases, each
with a specific importance. A Load factor of 0 eliminates all Loads having that
Load Case from the calculation.
In the example below, Load Case
number 1 represents the Dead Load or Permanent Load, which is given a Load
Factor of 1.35. Load Case 2 represents the Live or Imposed Load and is given a
Load Factor of 1.5. The Wind Load is assigned to Load Case 3 with a Load Factor
of 0.9.
The columns
refer to the different possible Load Combinations (from 1 to 9). Each Load
Combination column can have its unique set of Load Factors you want to
evaluate. By default, all load factors from Load Combinations 2 to 9 are set to
0.

When the
Loads on the Structure are being calculated, the contribution of the Self
Weight of the construction can be neglected or taken into account.
This choice
is made by the option Calculate or Neglect Self Weight in the
Structure Menu.
The own
Weight is calculated starting from the Mass M per meter (or per foot) as
indicated in the Cross-Sectional Data.
When the
temperature of the Structure changes, there will be equivalent Joint displacements . In case that Support
Joints restrict those
displacements, the structure will experience a Load.
With the
option Temperature from the Structure Menu, you can enter the temperature
difference in Kelvin between the temperature at which the construction is
build, and the temperature at which you want to calculate the structure.
The Linear
coefficient of expansion is given in the material list in 10-6 1/K.
Redraw
This Menu option redraws the screen.
Clicking the Redraw button from the tool bar has the same result.
Drawing Options
Here you
can change the options on the drawing: A shortcut key can also toggle most of
these options.
Drawing
By selecting these options, Forces,
Moments, Support Joints, Joint Displacements and Detailed Member Forces and
Stresses will be shown (when calculated). Forces and Moments are
represented by default in Red, except for moments in 3D structures that are
shown as purple arrows.
When the Detailed Member forces are
drawn, it is possible to show or hide the different Detailed Member forces with
the mouse. Click with the left mouse button on the name of the selected force
in the top left corner of the screen. Click again to redraw.
The factor to magnify the Forces,
Joint Displacements and Detailed Member Forces can be changed. By default, the
Joint Displacements are ten times exaggerated.
Numbering
By selecting the Joint and/or Member check box, the Joint numbers and/or Member numbers
will be shown in the drawing or the name of the cross sections will be
displayed.
This
option also allows you to visualize the values of the Utilization factor or
ratio for each member, based on the Member Design or Detailed Design results.
Values of the Utilization ratio >1 are displayed in red.
Viewing Angle
Here you can enter the horizontal
and vertical viewing angle. This only makes sense with a 3-dimensional
Structure. The horizontal Angle has to be between -360 and +360 , the vertical
viewing Angle between -90 and +90 . The default setting is 20* horizontal and
vertical.
The keyboard
The arrow
keys let you rotate the structure:
Ctrl arrow left / right :
changes the horizontal angle of view by 30 .
Ctrl arrow up / down :
changes the vertical angle of view by 30 .
Alt arrow left / right :
changes the horizontal angle of view by 10 .
Alt arrow up / down :
changes the vertical angle of view by 10 .
To view a
certain aspect of the structure:
Ctrl-F : Front view
Ctrl-L : Left view
Ctrl-R : Right view
Ctrl-T : Top view
Display or
hide features:
Ctrl-J : toggles the display of Joint
numbers.
Ctrl-M : toggles the display of Member numbers
or Section names.
Ctrl-S : toggles the display of the Structure
or the Displacements.
Ctrl-N : toggles the display of Detailed Member
Forces. Visualize the values of the Member Forces.
The Mouse
Zoom window: Press down the left
mouse button and move to select the window to zoom.
Select a Joint with the mouse by
clicking on the Joint Number:
Left mouse button: selects the Joint Number which turns red.
Right mouse button: deselects the Joint.
Double clicking the left mouse
button on a Joint Number lets you change or remove the Joint. Double clicking
on the blank screen, creates a new Joint.
Selecting two different Joints lets
you change, create or remove the Member between those Joints.
In that case an error message will
show The global construction is not stable . This means that there is a
shortage of Support restraints.

When you would only connect support
1 and support 3 with a beam (passing the location of support joint 2).
Analysis3D will not know that support 2 is actually connected to that same
beam. Analysis3D will see it as a loose support floating in the air at a point
that happens to be next to the beam, but unconnected. To make support 2
connected to that same beam you need one beam to go from support 1 to support 2
and a 2nd beam from support 2 to support 3.
The same goes for any connection.
Analysis3D requires that each connection is actually connecting all the joints
you want to be connected.
Another typical error message could
be The Structure is not consistent . This occurs when there are duplicate
joints with (almost) the same joint coordinates. Please remove the duplicate
joints to continue. The structure will also be not
consistent when one or more joints is not connected to the rest of the
structure.
Nonlinear or 2nd
order Calculation
In the
standard Calculation Analysis3D assumes that the original geometry can
be used throughout the analysis. This means that the loads are considered to be
fixed in position so that all forces and moments are constant and acting in the
same direction as the structure deforms. However, we know that this is actually
not the case. When a load is applied to a joint in a real structure, that joint
will move and the load will move with it. This movement of the load position
can change both the direction at which the load acts with respect to the
members connected to the joint, and the moment which the load causes about
other points in the structure. If the displacements are large enough, the
effect which the load have upon the structure can change significantly.
During
Nonlinear or 2nd order Calculation, Analysis3D takes into
account the deformed structure and incrementally calculates the effect on the
structure. Each increment uses the geometry of the structure due to the
application of the previous increment. Because of the incremental approach,
Nonlinear calculation takes somewhat longer to complete.
Sway
structures require 2nd order Calculations because of the magnitude
of the sway. Analysis3D allows you to check if structures are classified
as Sway or Non-Sway.
Very large structures can generate
an error message, because there is not enough free memory. To solve this
problem:
1. Close all other applications
before starting the computation. In some cases, it can be useful to restart
Windows.
2. Enlarge the virtual memory.
Analysis3D supports multitasking so that you can even start another copy of the
program while the calculation is busy.
The Drawing will automatically be
updated by showing the Joint Displacements (by default ten times exaggerated).
Finally, the Results can be
consulted.
Some standards require that the analysis
of the structure to determine the required strengths of the components uses
reduced stiffnesses. This reduction factor will be applied to all stiffnesses
in the structure.
A stiffness reduction factor of 0.8
will reduce the stiffness with 20% and displacements will increase accordingly.
The Joint Displacements are
presented in a table, and made visible on the screen. The Displacements are by
default ten times exaggerated in the drawing. Members that fail the
requirements for Member Stress or Buckling are indicated in red. The resulting
stresses are displayed in the corresponding list.
Displacements in [mm] or [inch] are
expressed in the Global Coordinate System as indicated in the bottom left
corner. Thus, a positive translation in the Y direction moves upwards.
The Rotations in [ ] are given
according the right-hand rule in the Global Coordinate System.
The Member Forces in [kN] or [Kips] and the Moments in [kNm]
or [Kips-ft] are given according to the Local Coordinate System.
The units are specified by the
Structure Menu option Units and Region.
With Trusses the Member Forces on
both sides are equal and opposite. So only the Member Force at the end Joint is
displayed. This conforms to the definition:
Positive Member Force = Tension
Negative Member Force = Compression
With Frames the Member Forces on
both sides can be different. Thus, the Member Forces on both Joints are
displayed.
On the top right of the screen, you
will find the total weight of the structure.
At the bottom right you can select
from the drop-down list, which Load Combination you want to use for visualizing
the results.
The Member Stresses in [N/mm ] or
[Kips/inch ] are presented according to the Local
Coordinate System.
The units are specified by the
Structure Menu option Units and Region.
With Trusses the Member Stresses on
both sides are equal and opposite. So only the Member Stress at the end Joint
is displayed. This conforms to the definition:
Positive Member Stress = Tension
Negative Member Stress = Compression
With Frames the Member Stresses on
both sides can be different. Thus, the Member Stresses on both Joints are
shown.
SAx :
the axial stress or strain.
SFy, SFz : the Shear stresses along the local y- respectively
z-direction.
The Shear stresses are calculated
according SFy = Fy . Sx / (tw . Ix).
This formula is reflecting that the
Shear Force is working on the area of the web of the section.
SBy, SBz : the Bending stresses along the local y-
respectively z-direction.
Bending Stress is calculated with SBz = Mz ex / Ix
STx :
the Torsional stress.
The Torsional Stress is calculated
with STx = Mx et / It.
SRes :
the Resulting Stress computed according Huber and Hencky (also referred to as Von Mises yield
criterion)
SRes = sqrt( SAx + SBy + SBz - SAx SBy SBy
SBz SBz SAx + 3SFy + 3SFz + 3STx )
In the case that the Structure is
two-dimensional the equation becomes:
SRes = sqrt( SAx + SBz - SAx
SBz + 3SFy )
So SRes is
not the real composed Member Stress but the ideal comparative stress that can
be compared with Yield Strength (Re) as defined in the material properties.
data, are highlighted in the list.
At the bottom right you can select
from the drop-down list, which Load Combination you want to use for visualizing
the results.
Sway
Stability is considered to determine if a structure is sway or non-sway. This
depends on the geometry and the load cases under consideration. It is
determined and influenced by the of P-delta effect.
Non-sway structures:
Horizontal loads are carried by the bracing or by horizontal support
Change of geometry (2nd-order effect) is negligible
Sway structures:
Horizontal loads are carried by the frame
Change of geometry (2nd-order effect) is significant
Analysis3D calculates for each story if it is sway or non-sway. In the case the
structure is classified as sway, 2nd order analysis is required. Analysis3D
allows you to calculate 2nd order effects in the case of Sway
structures.
In Eurocode 3 the
critical Sway ratio is determined as:

While ACI 318-19 works with the
invers stability index ratio:
The Natural Frequency of the
given structure is calculated using the formula below:

Where: Ktot
represents the total combined stiffness of the building and Mtot
equals the total mass.
The calculation of Buckling assumes that all Loads are entered with a
Load Factor.
The Load Factor is the ratio
between the Force used for the calculations and the real Force. This Load
Factor is by default set to 1.5. If any other Load Factor has been used, the
Load factor should be changed accordingly.
The Safety Factor depends
upon the conditions. For steel constructions a default Safety Factor of 2.5 is
used. Machine parts such as a piston rod need a Safety Factor of 4 to 10.
The resulting Maximum admissible
Buckling Load depends on the given Load Factor and Safety Factor.
For each compressed Member, the
slenderness and the Maximum admissible Buckling Load is calculated, taking into
account the Support restraints.
A distinction has to be made
dependent on the slenderness of the Member.
Slenderness = Member length / sqrt( I / Ax )
Eulers Limit Slenderness = 3,14 sqrt( E / 0,7 Re
) = 111 ( for FE360 )
Slenderness <= 20: In this area the maximum admissible strain will be reached long before
Buckling takes place. A computation on train is sufficient. The maximum
admissible Buckling Load will be: Ax . Re.
20 < Slenderness < Eulers Limit Slenderness: This
is the plastic area, where the present Stress may not exceed the Yield Point of
the material. The maximum admissible Buckling Load follows the straight line of
Von Tetmayer.
Slenderness > Eulers
Limit Slenderness: This is the elastic area
and can be calculated with Euler.
The maximum admissible Buckling Load
= 3,14 EI / (safety factor . buckling length )
At the bottom right you can select
from the drop-down list, which Load Combination you want to use for visualizing
the results.
Remarks:
In the calculation of the maximum
admissible Buckling Load the smallest radius of inertia is used. The program
will choose Ix or Iy. In Angle Cross Sections the
smallest radius of inertia (along the diagonal) is not available, this will
result in a minor aberration.
The maximum
limit Stress is set at 0,7 Re. This Stress corresponds to Eulers
limit Slenderness. Since this only applies to rolled Sections, the calculations
for Buckling only apply to these Sections.
The
Reaction Forces are calculated by adding the Member Forces in the Support Joints.
The Forces
in [kN] or [Kips] are oriented along the Global
Coordinate System as
indicated in the bottom left corner of the screen. Positive Reactions in the Y
direction are pointed up.
Moments in
[kNm] or [Kips-ft] are shown according the right-hand
rule in the Global Coordinate System.
The units
are specified by the Structure Menu option Units and Region.
At the bottom right you can select
from the drop-down list, which Load Combination you want to use for visualizing
the results.
The option Detail Member
Forces calculates for one Member the values of:
Axial (Normal) Forces (N)
Shear Forces (Ty and Tz)
Torsion (Mx)
Bending Moments (My and Mz)
Deflection (fy
and fz)
The sign definition for the member
Forces is as follows:
A Normal Force is positive, when it
induces Stress in the considered Section.
A Shear Force is positive, when it
rotates the released part to the left.
A Bending Moment is positive, when
she gives Stress in the part above the center of the Section.
Deflection is positive when it
coincides with the positive Local Coordinate System.
Thus, all Forces and Moments in the
following drawing are positive.

The number of divisions of
the Member can be set.
The calculation
shows the detailed member Forces in a table. The maximum values are
highlighted.
All Members selected from the list
to the right will be drawn together with their detailed member Forces.

At the bottom right you can select
from the drop-down list, which Load Combination you want to use for visualizing
the results.
The option Detail
Member Stresses calculates for one Member the course of:
Normal (Axial) Stress (SAx),
Shear Stress (SFy
en SFz),
Torsion Stress (STx)
Bending Stress (SBy
en SBz),
Deflection (fy)
Resulting Comparative Stress (SRes)
SRes is not the real composed Member
Stress but the Ideal Resulting Comparative Stress that can be compared with Re.
For the calculation of the Resulting
Comparative Stress see Member Stresses
The sign definition is equal as for
the Detail Member Forces:
The number of divisions
of the Member can be changed.
The maximum value for each stress is
highlighted, also any stresses that are not meeting the requirements versus the
Yield Strength Re, as given in the material data, are highlighted in the
list.
All Members selected from the list
to the right will be drawn together with their detailed Stresses.
At the bottom right you can select
from the drop-down list, which Load Combination you want to use for visualizing
the results.
This is a
powerful tool to optimize your construction in 2 ways.
If a given member is not strong
enough for the selected calculation method, Analysis3D will propose the
smallest cross-section from the list with Cross-sections. These members are
highlighted (selected) in the list with members.
If a given member is over designed,
then Analysis3D will propose you the cross-section with minimum area Ax that is
acceptable for the given load, to minimize cost.
Each cross-section can be checked in
the following different ways as selected in the Units and Region menu option:
- using the AISC-ASD standard
- using the AISC-LRFD standard
- using the BS 5950 standard
- using the Eurocode 3 standard
You can choose to use all or just
partly incorporate the proposed changes. After the changes are made, you need
to recalculate the structure to see the effect. You will find that because of
the changed sections, the forces in the structure are divided differently. This
means that other sections are no longer ideally dimensioned. You will find that
you may need a few iterations to come to the best solution.
Change button:
Just change the one selected member after the button with the proposed Section.
Before pressing this button, you can override the proposals by manually
changing the section or angle.
Change All button: Change all members with the proposed sections.
Only Selected button: Change the Section of the selected (highlighted) members. These
members are already selected for you and contain only those members that are
not strong enough. Of course, you can always change any selection you want.
Based on our experience this is the
best process to come to a structure with optimal sections.
1. Start with the first Load case
you have to evaluate. In this process you can use the Change All button
to find the smallest sections to minimize cost.
2. As you will move on by checking
the other Load cases for the same construction, you then can only change those
sections that are not strong enough. (Press the Only Selected button).
At the bottom right you can select
from the drop-down list, which Load Combination you want to use for calculating
the results.
Each cross-section can be checked in
the following different ways as selected in the Units and Region menu option:
- using the AISC ASD standard
- using the AISC LRFD standard
- using the BS 5950 standard
- using the Eurocode 3 standard
For each
method, Analysis3D will not only test the given Cross-sections, but will also
calculate optimized sections for the defined loads.
At the bottom right you can select
from the drop-down list, which Load Combination you want to use for visualizing
the results.
Design for Strength Using Allowable Strength Design according to
ANSI/AISC 360-16
Reference:
Specification for Structural Steel Buildings, July 7, 2016 AMERICAN INSTITUTE
OF STEEL CONSTRUCTION
Design
according to the provisions for allowable strength design (ASD) satisfies the
requirements of this Specification when the allowable strength of each
structural component equals or exceeds the required strength determined on the
basis of the ASD load combinations.
Design
shall be performed in accordance with the equation Ra ≤ Rn Ω
Where:
Ra = required strength using ASD load
combinations
Rn = nominal strength
Ω = safety factor
Rn/Ω = allowable strength
The nominal
strength, Rn, and the safety factor, Ω, for the applicable limit states
are specified below:
TENSILE STRENGTH: Ωt
= 1.67
COMPRESSION: Ωc
= 1.67
FLEXURE: Ωb = 1.67
SHEAR: Ωv = 1.67
TORSION: ΩT = 1.67
Allowable
Strength Design (ASD) requires 2nd order effects (P-Δ effect) to be included. This is
achieved by performing 2nd order analysis or by using a Moment
magnification factor. Analysis3D assumes ASD is performed on the results
of a Nonlinear or 2nd order Calculation before the ASD analysis is done
All
formulas and calculations are detailed in the LRFD design.
Design for
Strength Using Load and Resistance Factor Design (LRFD) according ANSI/AISC
360-16.
Reference: Specification for Structural Steel
Buildings, July 7, 2016 AMERICAN INSTITUTE OF STEEL CONSTRUCTION
Design according to the provisions
for load and resistance factor design (LRFD) satisfies the requirements of this
Specification when the design strength of each structural component equals or
exceeds the required strength determined on the basis of the LRFD load
combinations.
LRFD requires 2nd order effects (P-Δ
effect) to be included. Analysis3D assumes LRFD will by calculated using 2nd
order Analysis results and that the second-order analysis be carried out under
LRFD load combinations.
Classification of Sections for Local
Buckling
For members subject to axial
compression, sections are classified as nonslender-element
or slender-element sections. For a nonslender-element
section, the width-to-thickness ratios of its compression elements shall not
exceed λr from
Table B4.1a. If the width-to-thickness ratio of any compression element exceeds
λr, the section is
a slender-element section. For members subject to flexure, sections are
classified as compact, noncompact or slender-element sections. For a section to
qualify as compact, its flanges must be continuously connected to the web or
webs, and the width-to-thickness ratios of its compression elements shall not
exceed the limiting width-to-thickness ratios, λp, from Table B4.1b. If the width-to-thickness
ratio of one or more compression elements exceeds λp, but does not exceed λr from Table B4.1b, the section is
noncompact. If the width-to-thickness ratio of any compression element exceeds λr, the section is a slender-element
section



Design shall be performed in accordance with: Ru ≤ φRn
where Ru = required strength using LRFD load combinations
Rn = nominal strength
φ = resistance factor
φRn = design strength
Tension
For members designed on the basis of
tension, the slenderness ratio, L/r, preferably should not exceed 300.
The design tensile strength of
tension members is obtained according to the limit states of tensile yielding
in the gross section: Pn = Fy Ag
The resistance factor φt = 0.90
Compression
For members designed on the basis of
compression, the effective slenderness ratio, Lc /r, preferably should not
exceed 200.
The resistance factor φc = 0.90

FLEXURAL BUCKLING OF MEMBERS WITHOUT
SLENDER ELEMENTS
The nominal compressive strength, Pn, shall be determined based on the limit state
of flexural buckling: Pn = Fcr Ag
The critical stress, Fcr, is determined as follows:

TORSIONAL AND FLEXURAL-TORSIONAL
BUCKLING OF SINGLE ANGLES AND MEMBERS WITHOUT SLENDER ELEMENTS
The nominal compressive strength, Pn, shall be determined based on the limit
states of torsional and flexural-torsional buckling: Pn
= Fcr Ag
The critical stress, Fcr, is determined as above.
For doubly symmetric members twisting about the shear center:
![]()
For singly symmetric members twisting about the shear center where y is
the axis of symmetry:

For unsymmetric members twisting about the shear center, Fe is the
lowest root of the cubic equation:
![]()
MEMBERS WITH SLENDER ELEMENTS
The nominal compressive strength, Pn, shall be the lowest value based on the
applicable limit states of flexural buckling, torsional buckling, and
flexural-torsional buckling in interaction with local buckling.
Pn = Fcr
Ae
Slender Element Members Excluding
Round HSS: The effective width, be, (for tees, this is de; for webs, this is
he) for slender elements is determined as follows:

and ![]()

Round HSS:
The effective area, Ae,
is determined as follows:

DESIGN OF MEMBERS FOR FLEXURE
For guidance in determining the
appropriate sections of this chapter to apply the table below is used.

The design flexural strength, φbMn shall be determined using φb = 0.90
DOUBLY SYMMETRIC COMPACT I-SHAPED
MEMBERS AND CHANNELS BENT ABOUT THEIR MAJOR AXIS
The nominal flexural strength, Mn,
shall be the lower value obtained according to the limit states of yielding
(plastic moment) and lateral-torsional buckling.
Yielding: Mn = Mp = Fy Zx
Lateral-Torsional Buckling:
-
When Lb ≤ Lp,
the limit state of lateral-torsional buckling does not apply.
- When Lp < Lb ≤ Lr :
![]()
with
and ![]()
-
When Lb > Lr :
Mn = Fcr Sx ≤ Mp
with
and ![]()
DOUBLY SYMMETRIC I-SHAPED MEMBERS
WITH COMPACT WEBS AND NONCOMPACT OR SLENDER FLANGES BENT ABOUT THEIR MAJOR AXIS
The nominal flexural strength, Mn,
shall be the lower value obtained according to the limit states of
lateral-torsional buckling and compression flange local buckling.
For lateral-torsional
buckling: the provisions of the previous paragraph shall apply.
Compression Flange Local
Buckling:
(a) For sections with noncompact flanges: ![]()
(b) For sections with slender flanges: ![]()
OTHER I-SHAPED MEMBERS WITH COMPACT
OR NONCOMPACT WEBS BENT ABOUT THEIR MAJOR AXIS
The nominal flexural strength, Mn,
shall be the lowest value obtained according to the limit states of compression
flange yielding, lateral-torsional buckling, compression flange local buckling,
and tension flange yield.
Compression Flange
Yielding: Mn = Rpc
Myc
with Myc = Fy Sxc = yield moment in the compression flange
and ![]()
Lateral-Torsional
Buckling:
When Lb
≤ Lp, the limit state of
lateral-torsional buckling does not apply.
When Lp
< Lb ≤ Lr
: ![]()
When Lb
> Lr : Mn = Fcr Sxc
≤ Rpc Myc
With
and 
where
and
Compression Flange Local Buckling:
For sections with
compact flanges, the limit state of local buckling does not apply.
For sections with
noncompact flanges: ![]()
For sections with
slender flanges: ![]()
DOUBLY SYMMETRIC AND SINGLY
SYMMETRIC I-SHAPED MEMBERS WITH SLENDER WEBS BENT ABOUT THEIR MAJOR AXIS
Compression Flange Yielding: Mn
= Rpg Fy
Sxc
where ![]()
Lateral-Torsional Buckling: Mn
= Rpg Fcr
Sxc
When Lb ≤ Lp,
the limit state of lateral-torsional buckling does not apply.
When Lp < Lb
≤ Lr:
When Lb > Lr:

Compression Flange Local
Buckling: Mn = Rpg Fcr Sxc
For sections with compact flanges, the limit state of compression flange
local buckling does not apply.
For sections with
noncompact flanges: ![]()
For sections with
slender flanges: 
I-SHAPED MEMBERS AND CHANNELS BENT
ABOUT THEIR MINOR AXIS
Yielding: Mn = Mp = Fy Zy ≤ 1.6 Fy
Sy
Flange Local Buckling:
For sections with compact flanges, the limit state of flange local
buckling does not apply.
For sections with noncompact flanges:
For sections with slender flanges: Mn = Fcr
Sy where 
SQUARE AND RECTANGULAR HSS AND BOX
SECTIONS
Yielding: Mn = Mp = Fy Z
Flange Local Buckling:
For compact sections,
the limit state of flange local buckling does not apply.
For sections with
noncompact flanges: ![]()
For sections with
slender flanges: Mn = Fy Se

Web Local Buckling
For compact sections, the limit state of web local buckling does not
apply.
For sections with noncompact webs: ![]()
For sections with slender webs:
Compression flange yielding: Mn = Rpg Fy
S
Compression flange local buckling: Mn
= Rpg Fcr
Sxc
and 
Lateral-Torsional Buckling
When Lb ≤ Lp,
the limit state of lateral-torsional buckling does not apply.
When Lp < Lb ≤ Lr: ![]()
When Lb > Lr: ![]()
with
and ![]()
ROUND HSS
Yielding: Mn = Mp = Fy Z
Local Buckling:
For compact sections, the limit state of flange local buckling does not
apply.
For noncompact sections:
For sections with slender walls: Mn = Fcr S with ![]()
TEES AND DOUBLE ANGLES LOADED IN THE
PLANE OF SYMMETRY
Yielding:
For tee stems and web legs in tension Mp
= FyZx ≤ 1.6 Fy Sx
For tee stems in compression Mp = Fy Sx
Lateral-Torsional Buckling
For stems and web legs in tension
When Lb ≤ Lp,
the limit state of lateral-torsional buckling does not apply.
When Lp < Lb ≤ Lr:
When Lb > Lr: Mn = Mcr with 
where 
For stems and web legs in compression anywhere along the unbraced
length: Mn = Mcr ≤ Fy Sx
with ![]()
Flange Local Buckling
For sections with a compact flange in flexural compression, the limit
state of flange local buckling does not apply.
For sections with a noncompact flange in flexural compression:
For sections with a slender flange in flexural compression: 
Local Buckling of Tee Stems in
Flexural Compression: Mn = Fcr
Sx

SINGLE ANGLES
Yielding: Mn = 1.5
My
Lateral-Torsional Buckling:

For equal-leg angles with no axial compression: ![]()
For other angles: ![]()
Leg Local Buckling:
For compact sections, the limit state of leg local buckling does not
apply.
For sections with noncompact legs: ![]()
For sections with slender legs: Mn = Fcr Sc with
RECTANGULAR BARS AND ROUNDS
Yielding: for rounds and for
rectangular bars with
: Mn = Mp
= Fy Z ≤ 1.6 Fy Sx
Lateral-Torsional Buckling:
For rectangular bars with
bent about their major axis, the limit
state of lateral-torsional buckling does not apply.
For rectangular bars with
: ![]()
For rectangular bars with
: Mn = Fcr Sx ≤
Mp where ![]()
DESIGN OF MEMBERS FOR SHEAR
The design shear strength, φv Vn shall
be determined using φv = 0.90
and the nominal shear strength, Vn, shall
be determined according to the sections below.
I-SHAPED MEMBERS AND CHANNELS
Shear Strength of Webs without
Tension Field Action:
The nominal shear strength: Vn = 0.6 Fy
Aw Cv1
For webs of rolled I-shaped members with
Cv1 = 1.0
For all other I-shaped members and channels:
when
: Cv1
= 1.0
when
: ![]()
with kv = 5.34
SINGLE ANGLES AND TEES
The nominal shear strength of a
single-angle leg or a tee stem is: Vn
= 0.6 Fy b t Cv2

RECTANGULAR HSS, BOX SECTIONS, AND OTHER
SINGLY AND DOUBLY SYMMETRIC MEMBERS
The nominal shear strength Vn = 0.6 Fy
Aw Cv2
ROUND HSS
Vn = Fcr
Ag / 2
WEAK-AXIS SHEAR IN DOUBLY SYMMETRIC
AND SINGLY SYMMETRIC SHAPES
For doubly and singly symmetric
shapes loaded in the weak axis without torsion, the nominal shear strength for
each shear resisting element is: Vn
= 0.6 Fy bf tf
Cv2
DESIGN OF MEMBERS FOR COMBINED
FORCES AND TORSION
DOUBLY AND SINGLY SYMMETRIC MEMBERS
SUBJECT TO FLEXURE AND AXIAL FORCE
Doubly and Singly Symmetric Members
Subject to Flexure and Compression or Tension:
The interaction of flexure and
compression or tension in doubly symmetric members and singly symmetric members
constrained to bend about a geometric axis (x and/or y) shall be limited by the
Equations:

Doubly Symmetric Rolled Compact
Members Subject to Single-Axis Flexure and Compression
If Mry/Mcy <= 0.05 :
For the limit state of in-plane instability, the previous Equations
shall be used with Pc taken as the available compressive strength in the plane
of bending and Mcx taken as the available flexural
strength based on the limit state of yielding.
For the limit state of out-of-plane buckling and lateral-torsional
buckling: ![]()
UNSYMMETRIC AND OTHER MEMBERS
SUBJECT TO FLEXURE AND AXIAL
FORCE
![]()
MEMBERS SUBJECT TO TORSION AND
COMBINED TORSION, FLEXURE, SHEAR, AND/OR AXIAL FORCE
Round and Rectangular HSS Subject to
Torsion
The design torsional strength, φT Tn for round and rectangular HSS
according to the limit states of torsional yielding and torsional buckling
shall be determined as follows: Tn = Fcr
C and φT = 0.90
For round HSS, Fcr
shall be the larger of:
and
but shall not exceed 0.6 Fy
For rectangular HSS:

HSS Subject to Combined Torsion,
Shear, Flexure and Axial Force
When Tr exceeds 20% of Tc, the interaction of torsion, shear, flexure
and/or axial force shall be limited by ![]()
To summarize the maximum utilization
ratio is specified which should be ≤ 1.
The utilization ratio is a measure
for how close a section is to using its maximal section capacity and is
obtained by the ratio between the applied loads and the loads at the design
resistance.
BS 5950 starts from the
classification of sections into 4 categories: Plastic, Compact, Semi-compact or
Slender. The classification of the cross-section will determine the way the
allowable stress is determined.
Analysis3D will evaluate Plastic,
Compact, Semi-compact sections. Slender sections are beyond the scope of
Analysis3D.
When using the BS 5950 code,
Analysis3D design assumes that a 2nd order analysis has already been
performed, so that moment magnification factors for the moments causing
side-sway can be taken as unity.
Each cross-section is tested for:
- Compression Resistance
- Tension Capacity
- Shear Capacity
- Moment capacity
- Lateral-Torsional Buckling Moment Capacity
- Local Capacity Check
- Overall Buckling Check
CISC 94
starts for the determination of the nominal strengths for axial compression and
flexure, the sections are classified as either Class 1 (Plastic), Class 2
(Compact), Class 3 (Noncompact), or Class 4 (Slender). If a section fails to
satisfy the limits for Class 3 sections, the section is classified as Class 4.
Currently Analysis3D does not check stresses for Class 4 sections.
When using
the CISC 94 code, Analysis3D assumes that a P- analysis has been performed so
that moment magnification factors for moments causing sidesway can be taken as
unity.
The
strength reduction factor is taken as 0.9 (CISC 13.1)
Each cross-section is tested for:
-
Compression Strength
-
Tension Strength
-
Bending Strength
-
Shear Strength
-
Capacity Ratio for Compressive Axial
and Bending Stresses
-
Capacity Ratio for Tensile Axial and
Bending Stresses
The Eurocode 3 (EN 1993-1-1: 2005)
standard first evaluates the section and defines a section class depending
on the cross-section properties and the section load combination. The section
class will determine the method of analysis.
-
Class 1 cross-sections are those which can form a
plastic hinge with the rotation capacity required from plastic analysis without
reduction of the resistance.
-
Class 2 cross-sections arc those which can develop
their plastic moment resistance, but have limited rotation capacity because of
local buckling.
-
Class 3 cross-sections are those in which the stress
in the extreme compression fiber of the steel member assuming an elastic
distribution of stresses can reach the yield strength, but local buckling is
liable to prevent development of the plastic moment resistance.
-
Class 4 cross-sections are those in which local
buckling will occur before the attainment of yield stress in one or more parts
of the cross-section.
Classification of Sections:



A cross-section is classified
according to the highest (least favorable) class of its compression parts.
Class 4 cross-sections are beyond
the scope of Analysis3D.
When using
Eurocode 3, Analysis3D design assumes that a P- analysis or 2nd
order analysis has been performed so that moment magnification factors for
moments causing sidesway can be taken as unity.
No
allowance is made for fastener holes. This is outside of the scope of
Analysis3D and requires separate investigation.
The nominal
strengths in compression, tension, bending, and shear are computed for Class 1,
2, and 3 sections according to the following subsections. The material partial
safety factors used by the program are:
Tension: The design value of the tension
force NEd at each cross section shall
satisfy:
and the
design expression for yielding of the gross cross-section (plastic resistance)
is given as:

Compression: The design value of the compression
force NEd at each cross-section shall
satisfy:
and

Bending
moment: The design
value of the bending moment MEd at each cross-section shall satisfy:
with 
Shear: The design value of the shear force
VEd at each cross section shall satisfy:

For plastic design is the design
plastic shear resistance VpLRd is given
as:
If
then
additional shear buckling check is required by
where
and ![]()
Combined
bending and shear:
Where the
shear force is less than half the plastic shear resistance its effect on the
moment resistance may be neglected. Otherwise, the reduced moment resistance
should be taken as the design resistance of the cross-section, calculated using
a reduced yield strength ![]()
where
![]()
Combined
bending and axial force:
For class 1
and 2 cross sections, the following criterion shall be satisfied:
![]()
For a
rectangular solid sections:
![]()
For I sections:

For
bi-axial bending the following criterion may be used:

For Class 3
cross-sections the maximum longitudinal stress shall satisfy the criterion:
![]()
Combined
bending, shear and axial force:
Where VEd exceeds 50% of Vpl,Rd the design resistance of the
cross-section to combinations of moment and axial force should be calculated
using a reduced yield strength
for the shear area
where
![]()
Buckling
resistance:
The design
compression force NEd shall
satisfy:
![]()
where
![]()
and

The
non-dimensional s1enden1ess is given by
![]()
with
![]()
Torsional
and torsional-flexural buckling:
For
torsional and torsional-flexural buckling the slenderness is calculated as:
![]()
where Ncr = Ncr,TF
but Ncr < Ncr,T
Ncr,TF is the elastic critical
torsional flexural buckling force
Ncr,T is the elastic critical torsional
buckling force
![]()
![]()
and

Buckling
resistance in bending:
Laterally
unrestrained members subject to major axis bending are verified against
lateral- torsional buckling as follows:
![]()
where
The Lateral
torsional buckling curves General case
![]()

![]()
The Lateral
torsional buckling curves for rolled sections or equivalent welded sections
For rolled
or equivalent welded sections in bending the values of XLT for the appropriate
nondimensional slenderness may be determined as:
and
![]()
Uniform
members in bending and axial compression:
Members
which are subjected to combined bending and axial compression should satisfy:

The values
of the interaction factors are give
below:


![]()
To summarize the maximum utilization
factor is specified which should be ≤ 1.
The utilization factor is a measure
for how close a section is to using its maximal section capacity and is
obtained by the ratio between the applied loads and the loads at the design
resistance.
The five
lines enable you to enter a Heading, for your printed output. Since the Heading
is saved with the configuration file, it will stay unchanged after rebooting.
Structural
Data:
-Joints and Support Joints
-Members
-Joint Loads
-Member Loads
-Cross Section Data
-Material Data
If the
construction is calculated, Analysis3D will also print the results:
-Joint Displacements
-Member Forces
-Member Stresses
-Buckling
-Reactions
-Detailed Member Forces
Detailed
Design
This option
will send the results of the detailed design calculations to the printer.
Drawing
The
presented drawing is copied to the printer as shown on the screen.
Printer
Setup
This option
allows you select your printer and paper together with changing your printing
properties.
Please read this End-User License
Agreement carefully before downloading or using Analysis3D.
The words of which the initial letter is
capitalized have meanings defined under the following conditions. The following
definitions shall have the same meaning regardless of whether they appear in
singular or in plural.
For the purposes of this End-User License
Agreement:
Agreement means this
End-User License Agreement that forms the entire agreement between You and the
Company regarding the use of the Application.
Application means
the software program provided by the Company downloaded by You to a Device,
named Analysis3D
Company (referred to
as either "the Company", "We", "Us" or
"Our" in this Agreement) refers to Cuylaerts Engineering.
Content refers to
content such as text, images, or other information that can be posted,
uploaded, linked to or otherwise made available by You, regardless of the form
of that content.
Country refers to Belgium
Device means any
device that can access the Application such as a computer, a cellphone or a
digital tablet.
Third-Party Services means
any services or content (including data, information, applications and other
products services) provided by a third-party that may be displayed, included or
made available by the Application.
You means the individual accessing
or using the Application or the company, or other legal entity on behalf of
which such individual is accessing or using the Application, as applicable.
By clicking the "I Agree"
button, downloading or using the Application, you are agreeing to be bound by
the terms and conditions of this Agreement. If You do not agree to the terms of
this Agreement, do not click on the "I Agree" button, do not download
or do not use the Application.
This Agreement is a legal document between
You and the Company and it governs your use of the Application made available
to You by the Company.
The Application is licensed, not sold, to
You by the Company for use strictly in accordance with the terms of this
Agreement.
The Company grants You a revocable,
non-exclusive, non-transferable, limited license to download, install and use
the Application strictly in accordance with the terms of this Agreement.
The license that is granted to You by the
Company is solely for your personal, non-commercial purposes strictly in
accordance with the terms of this Agreement.
You
are not permitted to
- Sell,
transmit, host or otherwise commercially exploit our application
- Copy
or use our application for any other purposes except for personal,
non-commercial purposes
- Modify,
decrypt, reverse compile or reverse engineer our application
The Application may display, include or
make available third-party content (including data, information, applications
and other products services) or provide links to third-party websites or
services.
You acknowledge and agree that the Company
shall not be responsible for any Third-party Services, including their
accuracy, completeness, timeliness, validity, copyright compliance, legality,
decency, quality or any other aspect thereof. The Company does not assume and
shall not have any liability or responsibility to You or any other person or
entity for any Third-party Services.
You must comply with applicable Third
parties' Terms of agreement when using the Application. Third-party Services
and links thereto are provided solely as a convenience to You and You access
and use them entirely at your own risk and subject to such third parties' Terms
and conditions.
This Agreement shall remain in effect
until terminated by You or the Company. The Company may, in its sole
discretion, at any time and for any or no reason, suspend or terminate this
Agreement with or without prior notice.
This Agreement will terminate immediately,
without prior notice from the Company, in the event that you fail to comply
with any provision of this Agreement. You may also terminate this Agreement by
deleting the Application and all copies thereof from your Device or from your
computer.
Upon termination of this Agreement, You shall cease all use of the
Application and delete all copies of the Application from your Device.
Termination of this Agreement will not
limit any of the Company's rights or remedies at law or in equity in case of
breach by You (during the term of this Agreement) of any of your obligations
under the present Agreement.
You agree to indemnify and hold the
Company and its parents, subsidiaries, affiliates, officers, employees, agents,
partners and licensors (if any) harmless from any claim or demand, including
reasonable attorneys' fees, due to or arising out of your: (a) use of the
Application; (b) violation of this Agreement or any law or regulation; or (c)
violation of any right of a third party.
The Application is provided to You
"AS IS" and "AS AVAILABLE" and with all faults and defects
without warranty of any kind. To the maximum extent permitted under applicable
law, the Company, on its own behalf and on behalf of its affiliates and its and
their respective licensors and service providers, expressly disclaims all
warranties, whether express, implied, statutory or otherwise, with respect to
the Application, including all implied warranties of merchantability, fitness
for a particular purpose, title and non-infringement, and warranties that may
arise out of course of dealing, course of performance, usage or trade practice.
Without limitation to the foregoing, the Company provides no warranty or
undertaking, and makes no representation of any kind that the Application will
meet your requirements, achieve any intended results, be compatible or work
with any other software, applications, systems or services, operate without
interruption, meet any performance or reliability standards or be error free or
that any errors or defects can or will be corrected.
Without limiting the foregoing, neither
the Company nor any of the company's provider makes any representation or
warranty of any kind, express or implied: (i) as to
the operation or availability of the Application, or the information, content,
and materials or products included thereon; (ii) that the Application will be
uninterrupted or error-free; (iii) as to the accuracy, reliability, or currency
of any information or content provided through the Application; or (iv) that
the Application, its servers, the content, or e-mails sent from or on behalf of
the Company are free of viruses, scripts, trojan horses, worms, malware,
timebombs or other harmful components.
Some jurisdictions do not allow the
exclusion of certain types of warranties or limitations on applicable statutory
rights of a consumer, so some or all of the above exclusions and limitations
may not apply to You. But in such a case the exclusions and limitations set
forth in this section shall be applied to the greatest extent enforceable under
applicable law. To the extent any warranty exists under law that cannot be
disclaimed, the Company shall be solely responsible for such warranty.
Notwithstanding any damages that You might
incur, the entire liability of the Company and any of its suppliers under any
provision of this Agreement and your exclusive remedy for all of the foregoing
shall be limited to the amount actually paid by You for the Application or
through the Application or 100 USD if You haven't purchased anything through
the Application.
To the maximum extent permitted by
applicable law, in no event shall the Company or its suppliers be liable for
any special, incidental, indirect, or consequential damages whatsoever
(including, but not limited to, damages for loss of profits, loss of data or
other information, for business interruption, for personal injury, loss of
privacy arising out of or in any way related to the use of or inability to use
the Application, third-party software and/or third-party hardware used with the
Application, or otherwise in connection with any provision of this Agreement),
even if the Company or any supplier has been advised of the possibility of such
damages and even if the remedy fails of its essential purpose.
Some states/jurisdictions do not allow the
exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to You.
If any provision of this Agreement is held
to be unenforceable or invalid, such provision will be changed and interpreted
to accomplish the objectives of such provision to the greatest extent possible
under applicable law and the remaining provisions will continue in full force
and effect.
Except as provided herein, the failure to
exercise a right or to require performance of an obligation under this
Agreement shall not affect a party's ability
to exercise such right or require such performance at any time thereafter nor
shall be the waiver of a breach constitute a waiver of any subsequent breach.
The Company does not make any warranties
concerning the Application.
You represent and warrant that (i) You are not located in a country that is subject to the
United States government embargo, or that has been designated by the United
States government as a "terrorist supporting" country, and (ii) You
are not listed on any United States government list of prohibited or restricted
parties.
The Company reserves the right, at its
sole discretion, to modify or replace this Agreement at any time. If a revision
is material, we will provide at least 30 days' notice prior to any new terms
taking effect. What constitutes a material change will be determined at the
sole discretion of the Company.
By continuing to access or use the
Application after any revisions become effective, You agree to be bound by the revised terms. If
You do not agree to the new terms, You are
no longer authorized to use the Application.
The laws of the Country, excluding its
conflicts of law rules, shall govern this Agreement and your use of the
Application. Your use of the Application may also be subject to other local,
state, national, or international laws.
The Agreement constitutes the entire
agreement between You and the Company regarding your use of the Application and
supersedes all prior and contemporaneous written or oral agreements between You
and the Company.
You may be subject to additional terms and
conditions that apply when You use or purchase other Company's services, which
the Company will provide to You at the time of such use or purchase.
If you have any questions about this
Agreement, please contact Us: